For infrastructure investors & TowerCos

See the technical risks. Understand the CAPEX. Unlock the value.

Infrastructure investment decisions depend on the quality of the underlying asset data. TriDyme brings together AI-assisted document intelligence, BIM and structural engineering to turn fragmented tower records into actionable portfolio insights.

Built on real-world telecom structural engineering expertise.

Thousands of assets. Fragmented evidence. Material decisions.

Technical data rooms often contain inconsistent inventories, legacy drawings, incomplete inspections and engineering reports produced over many years. These gaps complicate acquisition screening and future investment planning.

Uncertain technical exposure

Identify missing evidence, conflicting records and potential structural issues that deserve further investigation.

Unclear future CAPEX

Build transparent, assumption-driven scenarios for engineering investigations and potential reinforcement needs.

Limited portfolio visibility

Move from isolated site files to a comparable, traceable view across assets and geographies.

One technical intelligence layer. Three investment use cases.

Scoped project

Acquisition Due Diligence

Screen large tower portfolios, classify technical documentation, highlight data gaps and prioritize sites for engineering review.

  • Document inventory and completeness
  • Technical risk register
  • Evidence-linked findings
  • Investment-ready reporting
Platform

Portfolio Intelligence

Maintain a consolidated view of asset characteristics, technical evidence, risk status and planned interventions after acquisition.

  • Cross-portfolio dashboards
  • Asset-level technical records
  • Data quality and change tracking
  • CAPEX planning inputs
Engineering

Structural CAPEX Optimization

Connect portfolio insights to engineering assessments that can inform reinforcement strategies, site upgrades and capacity decisions.

  • Targeted structural analysis
  • Scenario comparison
  • Reinforcement design expertise
  • Engineering-led recommendations
Engineering and reinforcement →

From documents to portfolio decisions.

A fictional 16-site portfolio to illustrate the approach. No real data, no calculation performed.

Demo — 16 fictional sites, illustrative data
9sites with remaining capacity
5host one tenant with no works
7sites already over capacity
12.2average next-tenant cost (k€)
SiteTypeHeightRemaining capacityLimiting elementHosted with no works+1 tenant+2 tenants+3 tenants
Lattice tower36 m+14.2 m²Members (EC3)2no worksno works6,000 €
Monopole30 m+3.8 m²Members (EC3)04,500 €10,000 €27,500 €
Lattice tower45 m-9.5 m²Anchors028,500 €34,000 €39,500 €
Rooftop12 m+6.4 m²Supports1no works7,500 €13,000 €
Lattice tower40 m-2.1 m²Members (EC3)010,000 €27,000 €32,500 €
Monopole25 m+11.0 m²Members (EC3)1no works3,500 €9,000 €
Lattice tower50 m-21.7 m²Foundation039,500 €45,000 €50,000 €
Rooftop9 m+1.2 m²Supports07,000 €12,000 €29,500 €
Lattice tower36 m+8.9 m²Anchors1no works17,500 €22,500 €
Monopole35 m-4.6 m²Members (EC3)012,000 €29,500 €35,000 €
Lattice tower42 m-15.3 m²Anchors033,500 €39,000 €44,500 €
Rooftop15 m+4.1 m²Supports04,000 €9,500 €27,000 €
Lattice tower30 m+0.6 m²Members (EC3)07,500 €13,000 €30,000 €
Monopole28 m+17.5 m²Members (EC3)2no worksno works3,000 €
Lattice tower48 m-7.8 m²Foundation027,000 €32,500 €37,500 €
Monopole32 m-1.4 m²Anchors021,000 €26,500 €32,000 €

From one site to a reinforcement decision

On a fictional tower, add equipment or change the wind zone, then see what reinforcement changes, section by section.

36 m lattice tower · schematicDrag to rotate

Site configuration

Panel antennas
3
Microwave dishes
1
zone 2 · 24 m/s
Maximum work ratioCapacity available
62 %
  • T636 %
  • T542 %
  • T448 %
  • T353 %
  • T258 %
  • T162 %

The tower accepts this configuration: 62% in the most loaded section (T1).

Illustrative values to explain the principle: this is not an EN 1993-3-1 calculation note.

Evidence first. Engineering judgment always.

Five steps, from data room to action plan. AI supports extraction and triage; engineering conclusions and investment-sensitive assessments require qualified human review.

  1. Done by : TriDyme

    Connect the data room

    Import documents and asset inventories, with no migration.

    You getA document inventory, site by site.

  2. Done by : AI, reviewed by an engineer

    Structure the evidence

    Classify documents and extract key technical facts, each linked to its source.

    You getSourced technical data with a confidence level.

  3. Done by : AI, reviewed by an engineer

    Identify the gaps

    Detect missing documents and inconsistencies, then prioritize verification.

    You getA prioritized list of sites to verify.

  4. Done by : Engineer

    Assess the exposure

    Calculate remaining capacity and price reinforcement scenarios.

    You getA risk register and explicit CAPEX scenarios.

  5. Done by : Engineer

    Act on the insights

    Produce investment reporting and targeted technical action plans.

    You getA committee-ready report and an intervention plan.

Not another dashboard. Engineering intelligence behind every decision.

Structural engineering at the core

Real technical understanding of telecom towers, capacity and reinforcement. Our calculations are validated by the inspection body Socotec.

Traceable source-to-insight workflows

Every extracted fact and finding links back to its underlying document.

From analysis to action

Portfolio screening leads to detailed studies and practical reinforcement options, carried out by our teams in France.

Designed to complement existing systems

An intelligence layer that connects to your EAM, GIS and document management platforms rather than replacing them.

10,000+structures analysed
~2,000tower models developed
12,000structures analysed by the document chain
59%usable with no site visit

Results published by TriDyme on the telecom vertical.

Before acquisition. During ownership. At every upgrade.

Pre-acquisition

Screen technical data rooms and identify priority investigations.

Post-acquisition

Normalize records and establish a baseline portfolio view.

Portfolio operations

Monitor technical data quality, risks and intervention pipelines.

Network upgrades

Assess capacity and reinforcement scenarios for new equipment.

Start with a focused assessment. Scale with your portfolio.

  1. Portfolio Discovery Workshop

    Define scope, data availability, investment questions and success criteria.

  2. Paid Pilot Assessment

    Representative sample of sites, findings dashboard, technical review and recommendations.

  3. Portfolio Rollout

    Agreed data ingestion, reporting and optional ongoing monitoring.

Frequently asked questions

Does TriDyme replace our existing asset management software?

No. The approach is designed to complement existing asset, document and engineering systems, subject to integration scope.

Can you assess an entire portfolio without visiting every site?

We can screen available documentation across a portfolio and prioritize investigations. Physical condition and structural adequacy may require site visits, updated measurements and detailed engineering verification.

Are CAPEX forecasts guaranteed?

No. CAPEX scenarios depend on document quality, assumptions, site conditions and engineering validation. Findings are presented with uncertainty ranges and evidence status.

Can TriDyme support an independent technical adviser?

Yes. TriDyme can provide software, structured evidence and engineering analyses to support independent review, with responsibilities and potential conflicts of interest addressed contractually.

How is confidential transaction data handled?

Data is hosted in France, each client has its own environment, and your data never trains third-party models. Access rights, retention and hosting arrangements are defined for each engagement.

Know what you are buying. Know where to invest.

Explore how a focused technical assessment can bring greater clarity to your next infrastructure investment or tower portfolio.